No privacy disclosure.. Remote and non-contact detection.. Outputs the real-time breath rate and heart rate of the human body.. Detects and outputs the information that if the human body is in the bed to the connected client software. Counts the time in the bed and the time out of the bed.. Detects and outputs the human body movements to the connected client software, and counts the times of movements.. Supports transmitting data to platform by OTAP protocol.. Supports connecting to Wi-Fi.. Supports side mounting and cell mounting.
| Working Frequency | 60 to 63 GHz |
|---|---|
| Modulation Waveform | FMCW |
| Horizontal Detection Angle | ± 25° |
| Vertical Detection Angle | ± 10° |
| Max. Detectable Targets | Up to 1 target(s) |
| Detection Target Type | Human |
| Detection Distance | 2.7 m |
| Protocols | TCP/IP,ICMP,HTTP,HTTPS,FTP,SFTP,DHCP,DNS,DDNS,RTP,RTSP,RTCP,NTP,SMTP,SNMP,IGMP,802.1X,IPv4/IPv6,UDP,SSL/TLS,ISUP,ARP |
| API | ISAPI,SDK,OTAP |
| User/Host | Up to 16 users,3 user levels: administrator, operator, and user |
| Security | Password protection,Complicated password,HTTPS encryption,Basic and digest authentication for HTTP/HTTPS,RTP/RTSP over HTTPS,Control timeout settings,TLS 1.2,Host authentication (MAC address) |
| Web Browser | IE9 to IE11,Chrome V61+, IE9 to IE11, Firefox V41+, Edge |
| Client | Hik-Central Pro, Hik-Connect, Hik-Parter Pro |
| Network Interface | Wi-Fi,1 RJ45 10/100Mbps self-adaptive Ethernet port(s) |
| Indicator | Supported |
| General Function | Supports human body detection, body motion detection, and respiration and heart rate monitoring. |
| Power | DC 5 V, 2 A, max. 10 W, Type-C, PoE: 802.3af, Type 1, Class 3, max. 10 W |
| Material | PC |
| Dimensions | Ø90 mm × 81 mm (Ø3.54" × 3.19") |
| Package Dimensions | 419 mm × 319 mm × 307 mm (16.5" × 12.56" × 12.09") (L × W × H) |
| Weight | Approx. 130 g (0.29 lb.) |
| With Package Weight | Approx. 520 g (1.15 lb.) |
| Operating Condition | -10 °C to 50 °C (-14 °F to 122 °F). Humidity: 0% to 90% (non-condensing) |
| Storage Condition | -40 °C to 60 °C (-40 °F to 140 °F). Humidity 95% or less (Non-condensing) |
| Installation Height | Ceiling mount: height from the bed ≤ 2.7 m, Side mount (recommended mount): height from the bed = 1 m |
| EMC | CE-EMC: EN 55032: 2015/A11:2020+A1:2020, EN IEC61000-3-2: 2019/A1:2021, EN 61000-3-3: 2013+A1:2019/A2:2021, EN 50130-4: 2011 +A1: 2014 |
| RF | CE-RED: EN 305550-2 V1.2.1, EN 300328 V2.2.2, EN 301489-1 V2.2.3, EN 301489-52 V1.2.1, EN 301489-17 V3.2.4, EN IEC 62311:2020 |
| Safety | CB: IEC 61010-1: 2010, IEC 61010-1: 2010/AMD1: 2016, CE-LVD: EN 61010-1: 2010+A1: 2019 |
| Environment | CE-RoHS: 2011/65/EU, WEEE: 2012/19/EU, Reach: Regulation (EC) No 1907/2006 |
| Protection | IP54: IEC 60529: 1989+A1: 1999+A2: 2013 |